• +91-85699-09696

categories

Lighting and Building Control Systems Manufacturer, Suppliers and Exporter in India

Jaincolab Manufacturers is leading Lighting and Building Control Systems Manufacturer,and supplier and Exporter in India, Algeria (Algiers), Angola (Luanda), Argentina (Buenos Aires), Armenia (Yerevan), Australia(Canberra), Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.)

Last updated: 19 November 2026

What is in the lighting and building control systems range?

This range has three trainers for building services courses. Two cover security and fire alarm systems, and one covers direct digital control of heating, cooling, lighting and other building services. The solar trainers are in the Renewable Energy Equipment range, and the Electronic Control Trainer is in Power Electronics Trainers.

Trainer groups in the building control range

GroupItemsWhat it covers
Alarm systemsSecurity Alarm Trainer (JA-LABCS-9618), Fire Alarm Trainer (JA-LABCS-9625)Basic security and fire alarm systems for students and technicians who will install and maintain them
Building controlTraining System for DDC Control (JA-LABCS-9624)Configuration and programming of DDC units for heating, cooling, lighting, electrical and security services

Alarm and building control trainers compared

Each trainer is listed with the details its product page gives.

ProductProduct codeSubjectLearners or skillsMain components
Security Alarm TrainerJA-LABCS-9618Basic security alarm systemsStudents and technicians; installation and maintenanceEight-zone intruder alarm panel with four zones wired, one keypad, two PIR detectors, two magnetic door and window contacts, one tamper switch, indoor sounder, visual indicator and backup battery, on a 12 V DC training board that is not building protection
Fire Alarm TrainerJA-LABCS-9625Basic fire alarm systemsStudents and technicians; installation and maintenanceConventional four-zone fire alarm panel, two optical smoke detectors, one heat detector, two manual call points, one sounder, one visual alarm indicator, end-of-line parts and backup battery, with 24 V DC field devices
Training System for DDC ControlJA-LABCS-9624Direct digital control of heating, cooling, lighting, electrical and security services, and of industrial processesConfiguration, programming and set-up of DDC unitsProgrammable DDC controllers with universal I/O and BACnet/IP to a supervisory PC; temperature, humidity, carbon dioxide and occupancy sensors; 0 to 10 V damper actuators, fan, heater and lighting loads

How to choose a building alarm or control trainer

  • For alarm installation courses, choose the Security Alarm Trainer (JA-LABCS-9618) or the Fire Alarm Trainer (JA-LABCS-9625). The security trainer has an eight-zone panel with four zones wired, and the fire trainer a four-zone conventional panel. Both teach basic systems to students and technicians who will install and maintain them.
  • For building automation, the Training System for DDC Control (JA-LABCS-9624) covers configuration and programming of DDC units. Its controllers have universal inputs, binary inputs, analogue outputs and binary outputs, with BACnet/IP to a supervisory PC.
  • To test what happens when the mains fails, both alarm trainers have a backup battery. The fire alarm trainer also shows mains and battery failure on its panel.
  • To compare supply levels, use all three trainers. The security trainer works on a 12 V DC board and the fire trainer uses 24 V DC field devices. The DDC trainer uses a 24 V AC control transformer for its controllers and actuators.
  • For solar heating and solar power trainers, see the Renewable Energy Equipment range. For solid state relay and thyristor control, see Power Electronics Trainers.

Practicals covered by these trainers

TaskProducts used
Wiring and testing a basic security alarm systemSecurity Alarm Trainer
Wiring detectors and sounders to a fire alarm panel and testing the systemFire Alarm Trainer
Testing an alarm panel on its backup battery after a mains failureSecurity Alarm Trainer or Fire Alarm Trainer
Configuring and programming a DDC controller for a building serviceTraining System for DDC Control
Switching lighting by time schedule and occupancy, and tuning temperature, fan and damper loopsTraining System for DDC Control

Who uses these trainers

Polytechnics, ITIs, engineering colleges and vocational centres use these trainers in building services and electrical courses. The alarm trainer pages name students and technicians preparing for installation and maintenance work.

Ordering building alarm and control trainers

Quote the product code of each trainer. The product pages list the alarm panels, detectors and sounders, and the DDC controllers, I/O, sensors and software. All three trainers work from 230 V AC, 50 Hz mains. Send the list through our contact page.

Electrical ranges related to building control

Building alarm and control trainers are part of the Electronics Lab Equipments range from JaincoLab, an electronics lab equipment manufacturer in India.

RangeWhat it covers
Wiring, Distribution and ProtectionElectrical installation, circuit fault and electrical machine trainers
Renewable Energy EquipmentSolar heat, solar hot water and solar power trainers, with the Esave Ready To Go
Data Acquisition, Instrumentation and Process ControlPLC trainers, a conveyor system, process panels and temperature and level control trainers
Electrical TechnologyElectrical measurement, transformer and metering, and appliance repair trainers
Electrical Motor ControlA motor control circuit trainer, a motor generator system and sectioned motors
Variac DimmerstatsSingle phase and three phase variacs in panel and portable types
Electronic FundamentalsBasic electricity and electronics trainers, an operational amplifier trainer and automotive electrical trainers
Power Electronics TrainersSCR, triac and UJT trainers, thyristor converters, motor speed control and the Electronic Control Trainer for solid state relays
Breadboard TrainersBreadboard circuit labs, digital and analog labs, and logic trainers
Analog Electronics TrainerTraining boards for diodes, transistors, amplifiers, oscillators, filters and bridges
Digital Electronics TrainerLogic training boards for gates, flip-flops, counters, converters, multiplexers and decoders
OscilloscopesDual trace oscilloscopes, an oscilloscope with digital readout and a frequency counter
Digital Storage OscilloscopesDigital storage oscilloscopes, including dual channel and four channel models
Signal GeneratorsFunction generators, an AM and FM function generator and an RF signal generator
Communication TrainerAmplitude, frequency, pulse and phase modulation trainers, multiplexing and transmission line trainers
Radio and Telephone CommunicationsAM FM radio, CB transceiver, walkie talkie, mobile phone and microwave trainers

Frequently Asked Questions

How is a fire alarm zone different from a single-station alarm?
A zone groups several detectors and call points on one circuit, so the control panel shows which area raised the alarm. A single-station alarm sounds only at the detector itself. The Fire Alarm Trainer has a conventional four-zone control panel, so students can see which zone raised the alarm.

Why does an alarm keep sounding after the detector has cleared?
The alarm circuit latches. A relay or the control unit holds the alarm on after the detector signal ends, until someone resets the panel. This makes sure a brief alarm is not missed. On many security panels a timer silences the sounder after a set time, but the panel still shows the alarm until it is reset.

Why are sounders wired on a separate circuit from the detector zones?
Detector zones carry signals into the panel, while the sounder circuit carries power out to the sounders and visual indicators. Keeping them apart lets the panel watch each circuit for its own faults and still drive the sounders when a zone is damaged. On the Fire Alarm Trainer, students wire and test the two circuits separately.

How should the alarm and DDC trainers be reset after each class?
Clear every alarm and fault and leave each alarm panel unset, so the next group starts from a normal state. Load the saved starting program into the DDC controller. Note any damaged detector, lead or terminal for the technician before the trainers are put away.

Can our purchase committee see specification sheets or a demonstration before we order?
Yes. Each product page has a specification table and a photo that you can add to your file. A JaincoLab team can demonstrate the trainers to your purchase committee or at your institute, and a sample unit can be sent with the quotation if required. Ask through our contact page.

Is staff training included when the alarm and DDC trainers are installed?
JaincoLab service engineers install the trainers at your site and can show your staff the exercises, the alarm set and unset routines and the DDC programming tool. Service manuals are available with the trainers. Arrange the visit through our contact page.

For a quotation, list the trainers with their product codes and the number of sets you need, and send it through our contact page. For tender or project supply, see our tenders page.

Security Alarm Trainer

Security Alarm Trainer

Product Code : JA-LABCS-9618

Security alarm trainer on a 12 V DC monitored board: eight-zone panel with four zones wired, keypad, two PIR detectors, two door contacts, tamper switch, sounder, visual indicator and backup battery. A training board only, not building protection.

Note: Trainer for basic security alarm systems, for students and technicians learning installation and maintenance; a training board, not building protection. Manufactured by JaincoLab.

View Details
Training System for DDC Control

Training System for DDC Control

Product Code : JA-LABCS-9624

Training system for direct digital control (DDC) of heating, cooling, lighting, electrical and security services. Programmable controllers with universal I/O, BACnet over Ethernet, sensors, damper actuators and lighting loads.

Note: DDC training system for configuring, programming and setting up DDC units for building services, manufactured by JaincoLab.

View Details
Fire Alarm Trainer

Fire Alarm Trainer

Product Code : JA-LABCS-9625

Fire alarm trainer for students and technicians: conventional four-zone panel, two optical smoke detectors, one heat detector, two call points, sounder, visual alarm, end-of-line parts, backup battery and training manual, with 24 V DC field devices.

Note: Trainer for basic fire alarm systems, for students and technicians learning installation and maintenance, manufactured by JaincoLab.

View Details

Office Address

Jain Scientific Suppliers
2475-84, Hargolal Road,
Ambala Cantt, Haryana, India

[email protected]

+91-85699-09696

Follow Us